SF6 P1:p MANUAL Ion Science Ltd
34 of 41
Unrivalled Detection. www.ionscience.com
Technical data
SF6 LEAKCHECK P1p
Detector
NIC
©®
Detection limit,
Standard
1x10E-7 ml/s 1.0 ppm 0.01 g/a
Detection limit,
HIGHsens
1x10E-8 ml/s 0.1 ppm- 0.001 g/a
Measurement range
1x10E-5 ml/s - 999 ppm - 5 g/a
Response time t90
0.5 s approx.
Recovery time t10
0.5 s approx.
Alarms
Audible alarm, status LEDs, vibration alarm in the handset
Display
Handset analogue, base unit digital, plain text display
Self-diagnosis
Intake flow, sensor service life, condition of rechargeable battery, hardware faults
Battery
Integrated rechargeable battery with automatic charge control
Weight
Case 12,5 kg, handset 563 g
Operating temperature
0°C - 50°C
Operating voltage
100 -265 V 50/60Hz
Dimensions
Case 486 x 398 x 194 mm (max. plane carry on luggage 550 x 400 x 230 mm)
Storage temperature
range
-10°C - 60°C